Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 1.Missing HVAC ductwork and diffusers 2. Water hammer arrestors needed at laundry, ice maker and dishwasher 3. Smoke and carbon monoxide detectors needed 4. Provide hvac layout 5. Missing water heater 6. Toilet is too close to shower, need minimum of 15" from center of flange out. |