Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
10/07/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Called point of contact. Received no response. Got to the site and the lock box code that was given was incorrect. Reschedule at your convenience. 10/7/2026
10/08/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Framing has not been completed or approved. Sheathing requires blocking at edges to have the 6/12 nailing pattern. Decking missing nails through. Ensure nails do not over penetrate more than an 1/8". Beams are upside down and are not sitting completely on hardware. Rafters are not siting completely on beams. Double top plate has been over notched due to line set. Provide cs16 strap at corner to tie in walls. Stopped inspection. Other items will apply. 10/8/2026
10/13/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required (with fee) 10/13/26: add nails to h-3 at back patio beam, missing sd screws at each stud/ledger see detail 203, plans call HUS-212 hangers, missing C.C.Q.M at masonry piers, missing A-35's per detail 204, add nails to sheathing at marked locations and provide a ladder for roof access-ladder shall extend 3' above roof line. Stopped inspection-additional items may be noted.
10/16/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 10/16/2026
All corrections made.