Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0425-02223

Parcel: 115010270


Addresses:

2328 N 2ND AV

Inspection Status: Not Ready

Inspection History: COT - RSPL - Plumbing Final 

Date Description Inspector Results Comments
05/14/2025 COT - RSPL - Plumbing Final  Not Ready Called multiple times and left voicemails. Got to the site and gate was locked. Need access to site. 5/14/2025
05/16/2025 COT - RSPL - Plumbing Final  Re-inspection required No gauge at meter could not conduct pressure test. Trench shall be at least 18" deep. Yellow tracer wire required and secured along full length of non metallic gas piping. 05/16/2025
05/23/2025 COT - RSPL - Plumbing Final  Re-inspection required Failed, replace risers at meter and house with anodeless, and lower trench at meter location, reinspection required
06/02/2025 COT - RSPL - Plumbing Final  Passed