Parcel: 136203350


Addresses:

3760 S LE BEAUX PL


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-RES-0425-01770

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/01/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 7/1/25
1. Need to install HVAC
2. Damaged duct will need to be cleaned/replaced
3. All wiring needs to be brought up to code
4. All top plate penetrations will need to fire caulked
*****preliminary inspection*******More items will be added at intermediate.
10/31/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 10/31/25
1. Seal all top plate penetrations

2. Rafter of east side above window needs to be sistered or replaced due to large boring on the end of rafter.

3. Ensure we have CO detector just outside bedrooms; and smoke detectors in all sleeping areas.

4. Windows in all bedrooms will need to be brought down to 44 inches if they are being replaced.

5. If the kitchen is going to be on 20 amps circuits, wiring will need to be 12 AWG or lower.

6. Exhaust fans in bathrooms have kinked flex duct and one is missing duct. Please ensure fan is rated for the long run from bathroom to east side of house. Also the window will be a factor, the exhaust cannot be any closer than 36" above window and 10 ft horizontal from any window.
12/04/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready ok to cover progress areas, leave exhaust exposed for both bathrooms
12/08/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed