Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSPL - Plumbing Final
Permit Number - TC-RES-0425-01702
Inspection Description - COT - RSPL - Plumbing Final
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/06/2026 | COT - RSPL - Plumbing Final | Passed | ||
| 12/24/2025 | COT - RSPL - Plumbing Final | Re-inspection required | 12.24.25 Missing GFCI at laundry room Missing hammer arrester at hot line to dishwasher Address missing Breakers to livable spaces must be arc fault Need to verify fuses at ac disconnect (Current fuses are weathered and unreadable) Insulation needed at hot and cold copper at exterior water heater |