Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 09/25/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
9/25/24: Anchor bolts required 32" o.c per plans, sill plates at porch require 2 anchor bolts is larger than 12", compromised sill plate must be replaced, interior framing not per plans missing closet header and pop-outs revise plans to show changes made. 5/8" anchor bolts required per plan with 2" washers. |
| 10/10/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
|