Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Plumbing Final
| Date |
Description |
Inspector |
Results |
Comments |
| 04/25/2024 |
COT - RSPL - Plumbing Final |
|
Re-inspection required |
Not ready. Secure all pex lines. Insulate lines that are running through the attic space. Provide angle stops and shut off valves at first bath. Secure shower valves. Seal off all top penetrations. Provide 18" of copper at water heater. Provide hammer arrestor for dishwasher at hot line. Insulate water line at exterior wall front of home. Tape off copper that is touching other metals with 10 mil tape. 4/25/2024 |
| 05/03/2024 |
COT - RSPL - Plumbing Final |
|
Passed |
Corrections were made. 5/3/2024 |