Permit: TC-RES-0326-01452

Parcel: 118120390


Addresses:

310 E 22ND ST

Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
03/26/2026 COT - RSME - Mechanical Final  Re-inspection required 3/26/26
1. Missing T/P pipe
2. Vent needs to be secured
3. Water heater is not designed to be outside; recommend providing proper shelter to protect for elements. Current shelter is loose and missing the front door.
04/01/2026 COT - RSME - Mechanical Final  Not Ready
04/06/2026 COT - RSME - Mechanical Final  Re-inspection required (with fee) 4-6-26: secure vent with a clamp, hot copper side of water heater requires a minimum of R3 insulation, a 1 -1/2" air gap is required for T/P pipe, paint T/P pipe to protect against the elements.
04/23/2026 COT - RSME - Mechanical Final  Re-inspection required 4/23/26 Air gap required for T/P pipe, gas line required sediment trap
07/15/2026 COT - RSME - Mechanical Final  Passed 07/15/2026
Corrections made to prior inspection, verified created air gap at bottom of pressure relief pipe and painted.