Permit: TC-RES-0326-01333

Parcel: 133324160


Addresses:

9231 E HOLMES ST

Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
06/09/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready 6.9.26
1. Receptacle spacing not up to code need 2 more receptacles to meet code. One 6ft on the left side of door and another 6ft on the right side of door, and then the spacing becomes every 12ft.
2. Nail guards needed on studs with boring within 1.25" of stud edge.
3. Seal all top plate penetrations with fire caulk or fire putty.