Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/01/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 1. Southwest end of 15" Glulam there are 3 TJIs that need to be attached to ledger. 2. Plan is calling for shear wall and HTT4 holdowns at kitchen wall and bedroom wall on both sides of windows. 3. Please update plans to reflect these conditions. |
|
| 09/02/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 1. Southwest end of 15" Glulam there are 3 TJIs that need to be attached to ledger. 2. Plan is calling for shear wall and HTT4 holdowns at kitchen wall and bedroom wall on both sides of windows. 3. Please update plans to reflect that this work is not being completed. |
|
| 09/21/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass |