Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-RES-0325-01627
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/15/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 8.15.2025 Top plate on west wall of primary bedroom needs 2ft overlap from stud, missing a35 plate in primary bedroom rafter to ridge, porch rafters in rear needs H2.5 or equivalent. Add support on existing beams, add cripple studs underneath ridge at north wall in laundry room, add straps beam to post. Partial pass, okay to lath exterior. |
|
| 11/05/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |