| 09/17/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | Bottom plate is not pressure treated. Provide double layer of vapor barrier behind siding. Remove all drywall screws from clips and provide proper nails. Exterior wall has to have a double top plate. Exterior siding not nailed per schedule. Remove drywall screws from siding and provide proper fasteners. 9/17/2025 | |
| 10/01/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 10/1/25 see above notes | |
| 10/23/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | ||
| 11/03/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 11/3/25: all penetrations through top plate must be sealed, all penetrations through vapor barrier must be sealed, receptacle spacing at bedroom not per approved plans, smoke alarm missing in bedroom, nail plates required throughout, shower must be under test at time of inspection, exhaust fan must be terminated through the roof, missing run for light fixture in bedroom. | |
| 11/14/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |