Parcel: 130170320


Addresses:

4008 E 27TH ST


Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-RES-0325-01616

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Not Ready

Date Description Inspector Results Comments
09/17/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Bottom plate is not pressure treated. Provide double layer of vapor barrier behind siding. Remove all drywall screws from clips and provide proper nails. Exterior wall has to have a double top plate. Exterior siding not nailed per schedule. Remove drywall screws from siding and provide proper fasteners. 9/17/2025
10/01/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 10/1/25 see above notes
10/23/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready
11/03/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 11/3/25: all penetrations through top plate must be sealed, all penetrations through vapor barrier must be sealed, receptacle spacing at bedroom not per approved plans, smoke alarm missing in bedroom, nail plates required throughout, shower must be under test at time of inspection, exhaust fan must be terminated through the roof, missing run for light fixture in bedroom.
11/14/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed