Inspection Status: Re-inspection required
Inspection History: PDSD Building Division SIte Consultation
| Date |
Description |
Inspector |
Results |
Comments |
| 06/01/2026 |
PDSD Building Division SIte Consultation |
|
Re-inspection required |
6/1/26: all work has been completed prior to inspections being called in, electrical work must match approved plans, kitchen circuits must be GFCI and shall have a minimum of 2 small appliances circuits at kitchen, range exhaust missing at all units, mini splits must be listed and approved for US installation, disconnects required at mini splits, insulation at refrigerant lines must be properly secured and properly protected from UV exposure, approved plans must be revised to include (plumbing,mechanical), water heaters were replaced and unpermitted, electrical revision required for all changes, plumbing underground must be scoped to ensure compliance, window openings not code compliance, all exterior DWV must be properly secured and properly coated, receptacle spacing is over spanned throughout, exterior of home must he protected from weather. ADDITIONAL ITEMS MAY BE ADDED. |
| 06/05/2026 |
PDSD Building Division SIte Consultation |
|
Re-inspection required |
6/5/26: ladder required to access basement (existing access is in poor condition), |
| 06/10/2026 |
PDSD Building Division SIte Consultation |
|
Re-inspection required |
6/9/26: Crawl space appears in poor shape, supports of floor decking non code compliance, a structural engineer is required to assess the current state of supports, floor joist shall be no closer than 18” above earth and 12” for structural beams or girders. pex shall be properly supported and insulated, nm cable prohibited in wet/damp location, DWV must be tested for leaks, multiple incorrect fittings at DWV in crawl space, support DWV per code (4’ o.c),ground rod at crawl space must be in full contact with earth. |