Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0325-01416

Parcel: 121012290


Addresses:

2009 N CALLE SERENA

Inspection Status: Partial Pass

Inspection History: COT - RSPL - Sewer 

Date Description Inspector Results Comments
10/15/2025 COT - RSPL - Sewer  Partial Pass A revision has to be sent in due to new plumbing lines being installed with proper clean outs at in wall areas that are not included in the approved plans.
Partial pass. ADU are okay to backfill progress areas. Shading required. Plumbing at owners suite will be corrected due to drainage lines running parallel in footing. Note, 3" drainage line running near bedroom 3 will be moved over due to it being within the 45* from bottom of footing. Provide and secure 14 gauge green continuous tracer wire to drainage lines outside of slab. All other areas are okay to backfill. 10/15/2025
10/17/2025 COT - RSPL - Sewer  Passed