Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 1-Holes in rafters are less than 2" from edges. (P2603.2) 2-Install smoke detector per plan. 3-Flood light at North end is not on approved plans. 4-Light at door is not per approved plans. 5-Landing at door has negative slope. (R311.3 and IBC 104.1) |
|
| 08/28/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Partial Pass | 8/28/25 Ok to proceed, item five will be looked at on finals. Please call the inspection in along with finals to clear out item 5. Partial pass. |
|
| 09/19/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed |