Permit: TC-RES-0325-01224

Parcel: 120075420


Addresses:

4425 S 12TH AV

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
03/09/2026 COT - RSEL - Electrical Final  Re-inspection required 3/9/26: multiple receptacles have open ground, grounds and neutrals tied together at sub panel at patio, sub panel will need to be replaced as circuits are being tied in together at breakers, smoke detector required at bedroom, bathroom circuit tied into 40amp laundry circuit, multiple circuits tied in together. Properly label panel
04/03/2026 COT - RSEL - Electrical Final  Passed
08/26/2025 COT - RSEL - Electrical Final  Not Ready