Parcel: 12218381A


Addresses:

3501 E WILLARD ST


Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Permit Number - TC-RES-0324-01669

Inspection Description - RSBU - Building Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/15/2025 RSBU - Building Final  Re-inspection required 8.15.2025
Outdoor laundry room has receptacles with exposed wires, one receptacle is over-filled, and is using drywall screws to secure. Hot water heater PRV valve line needs to terminate between 24"-6" from grade, bathroom toilet doesn’t have 15” clearance from wall or 21" from the front to the shower, kitchen sink doesn’t have shutoff valves below, range oven is not secured from tilting. Roof AC needs paint for pvc condensate line, heat kit not specified, no flashing at roof jacks or electrical conduit.