Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
| Date |
Description |
Inspector |
Results |
Comments |
| 07/24/2024 |
COT - RSBU - Roof Nailing |
|
Re-inspection required |
7/24/24: sheathing loose in places check all roof nailing. |
| 08/06/2024 |
COT - RSBU - Roof Nailing |
|
Re-inspection required |
1-Remove and Renault all shiners. 2-Rafters do not have 1-1/2” minimum bearing required by Code. |
| 08/22/2024 |
COT - RSBU - Roof Nailing |
|
Re-inspection required |
8/22/24: roof has been covered with shingles. Need letter from registered contractor taking responsibility of roof stating it's to the minimum standards of the 2018 IRC CODE. |
| 09/13/2024 |
COT - RSBU - Roof Nailing |
|
Not Ready |
|
| 12/03/2024 |
COT - RSBU - Roof Nailing |
|
Passed |
|