Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 02/26/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
2-26-25, add anchor bolts per schedule for SW2(calls for 16" o.c.) add anchor bolts to to northeast corner-shot pins not allowed at external wall, add shot pins to marked locations at interior framing, add nails to exterior sheathing along edges-plans call for 6 o.c. Along edges and 12 " o.c. in the field- have framer check all sheathing joints at edges and correct any over penetrated nailing- crown of nails shall be flush and not over penetrated , add nails to loose roof sheathing at walk in closet located on west side between master bath and master bedroom. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. |
| 03/04/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
3/4/25 corrections made |