Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/06/2025 | RSBU - Building Final | Re-inspection required | 6/6/25 NO SITE ADDRESS: 1. NO SITE ADDRESS; Address shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). 2. Laundry GFCI IS TIED TO EXTERIOR 3. DISHWASHER NEEDS WATER HAMMER ARRESTOR 4. ENTRANCE THRESHOLD IS AT 3”, needs to be 1/2” max. 5. T-stat too high. 48” Max. |
|
| 06/09/2025 | RSBU - Building Final | Passed |