Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit: TC-RES-0324-01452

Parcel: 138080190


Addresses:

757 W CALLE ANTONIA

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Preslab  

Date Description Inspector Results Comments
05/07/2024 COT - RSBU - Preslab   Re-inspection required 5/7/24: reinforcement not in place at time of inspection, footing width and Length not per plan, F2 missing per plan
05/10/2024 COT - RSBU - Preslab   Re-inspection required 5/7/24: reinforcement not in place at time of inspection, footing width and Length not per plan, F2 missing per plan
5/10/24: per previous notes.
05/24/2024 COT - RSBU - Preslab   Canceled 5/7/24: reinforcement not in place at time of inspection, footing width and Length not per plan, F2 missing per plan
5/10/24: per previous notes.
5/24/24: canceled per contractor
05/31/2024 COT - RSBU - Preslab   Re-inspection required 5/7/24: reinforcement not in place at time of inspection, footing width and Length not per plan, F2 missing per plan
5/10/24: per previous notes.
5/24/24: canceled per contractor
5/31/24: footings not per plan.
06/05/2024 COT - RSBU - Preslab   Passed 5/7/24: reinforcement not in place at time of inspection, footing width and Length not per plan, F2 missing per plan
5/10/24: per previous notes.
5/24/24: canceled per contractor
5/31/24: footings not per plan.
6/5/24: reinforcement per plan ok to proceed