Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Date Description Inspector Results Comments
04/15/2026 COT - RSBU - Roof Nailing  Re-inspection required 04/15/2026
Add anchor bolts on exterior bearing walls and shot pins at interior walls as marked, add 2x4 studs 16" o.c. to west wall and 2x6 header with studs, missing jack studs on west large window not per plan - upload revision if different. Add two top bracing to A2M trusses per calcs.
05/12/2026 COT - RSBU - Roof Nailing  Not Ready
05/22/2026 COT - RSBU - Roof Nailing  Passed 05/22/2026
All corrections made to prior inspections.