Parcel: 140253120


Addresses:

5958 S STEWART BL


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-RES-0324-01301

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/05/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 8/5/24: king stud missing at sliding door opening, anchor bolt must be properly secured at sill plate at sliding door opening, king stud missing at master bedroom window opening , interior non-bearing walls must have shot pins 24" O.C and 12 from sill plate edge, anchor bolt spacing must be 48" O.C (over spanned throughout, properly secure anchor bolts throughout, properly support H2.5 clips throughout, exterior sheathing not fastened per schedule throughout, truss clacs must be left on site for inspection.
08/07/2024 COT - RSBU - Exterior Clips/Sheathing  Passed 8/5/24: king stud missing at sliding door opening, anchor bolt must be properly secured at sill plate at sliding door opening, king stud missing at master bedroom window opening , interior non-bearing walls must have shot pins 24" O.C and 12 from sill plate edge, anchor bolt spacing must be 48" O.C (over spanned throughout, properly secure anchor bolts throughout, properly support H2.5 clips throughout, exterior sheathing not fastened per schedule throughout, truss clacs must be left on site for inspection.
8/7/24: passed