Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSEL - Electrical Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/02/2024 | COT - RSEL - Electrical Final | Not Ready | ||
| 08/22/2023 | COT - RSEL - Electrical Final | Re-inspection required | Not ready. Called left a voicemail. Showed up to the site and no answer. Need access to site. 8/22/2023 | |
| 08/30/2023 | COT - RSEL - Electrical Final | Re-inspection required | Not ready. Called left a voicemail. Showed up to the site and no answer. Need access to site. 8/22/2023 8/30/23: secure NMC to mini-splits, label all breakers in all panels area specific, remove sub-panel from closet and install per plan or get a revision approved by COT, install light at egress door. This residential addition was not build per plan. |
|
| COT - RSEL - Electrical Final | Passed | 11/13/23: all corrections made | ||
| 12/12/2024 | COT - RSEL - Electrical Final | Re-inspection required | Add blank covers to all openings in sub panels. Re label sub panel. Disposal needs to be on a gfci. 12/12/2024 | |
| 12/20/2024 | COT - RSEL - Electrical Final | Passed | 12-20-24, required correction indicated from previous inspection have been made. Electrical final is approved. |