Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Preslab and floodplain
Permit Number - TC-RES-0323-03395
Inspection Description - COT - RSBU - Preslab and floodplain
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/06/2025 | COT - RSBU - Preslab and floodplain | Re-inspection required | 1-6-25, verified 3 #4 rebar top & bottom and #4 vertical at 32inches o.c. For unit 2130 and 2126. However, remove all loose fill throughout footers and wrap all conduit. If not done already, submit elevation certificate together with compaction report to the city portal for review and reschedule preslab when ready. | |
01/08/2025 | COT - RSBU - Preslab and floodplain | Not Ready | corrections not completed. | |
01/13/2025 | COT - RSBU - Preslab and floodplain | Not Ready | Please upload elevation certs for this inspection if you are unsure please visit PDSD for instructions | |
01/15/2025 | COT - RSBU - Preslab and floodplain | Re-inspection required | spoke with builder to explain that condition still has not been cleared. | |
01/17/2025 | COT - RSBU - Preslab and floodplain | Passed | ||
12/04/2024 | COT - RSBU - Preslab and floodplain | Re-inspection required | Provide address to verify pad for inspection. Lock box code incorrect. 12/4/2024 | |
12/06/2024 | COT - RSBU - Preslab and floodplain | Re-inspection required | 1-clear elevation certification condition. 2-Footings are not in to undisturbed soil. 3-Provide approved plans. 4-Provde Ufer. |