Date Description Inspector Results Comments
01/06/2025 COT - RSBU - Preslab and floodplain Re-inspection required 1-6-25, verified 3 #4 rebar top & bottom and #4 vertical at 32inches o.c. For unit 2130 and 2126. However, remove all loose fill throughout footers and wrap all conduit. If not done already, submit elevation certificate together with compaction report to the city portal for review and reschedule preslab when ready.
01/08/2025 COT - RSBU - Preslab and floodplain Not Ready corrections not completed.
01/13/2025 COT - RSBU - Preslab and floodplain Not Ready Please upload elevation certs for this inspection if you are unsure please visit PDSD for instructions
01/15/2025 COT - RSBU - Preslab and floodplain Re-inspection required spoke with builder to explain that condition still has not been cleared.
01/17/2025 COT - RSBU - Preslab and floodplain Passed
12/04/2024 COT - RSBU - Preslab and floodplain Re-inspection required Provide address to verify pad for inspection. Lock box code incorrect. 12/4/2024
12/06/2024 COT - RSBU - Preslab and floodplain Re-inspection required 1-clear elevation certification condition.
2-Footings are not in to undisturbed soil.
3-Provide approved plans.
4-Provde Ufer.