Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Rough Soil
Permit Number - TC-RES-0226-00750
Inspection Description - COT - RSPL - Rough Soil
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/27/2026 | COT - RSPL - Rough Soil | Re-inspection required | Provide a minimum of 12" depth at UG plumbing. Separation of lines in trench from main water and sewer is required. Separate drain line tie in from kitchen to laundry. Secure green 14 gauge wire to pipe throughout. Remove all rocks from trenches. Provide shading materials on site prior to next inspection. Re test system once corrections have been made. 2/27/2026 | |
| 03/04/2026 | COT - RSPL - Rough Soil | Passed | Corrections have been made. Okay to backfill. Shading required 3/4/2026 |