Inspection Status: Re-inspection required
Inspection History: COT - BULD - SWG Clearance
| Date |
Description |
Inspector |
Results |
Comments |
| 02/17/2026 |
COT - BULD - SWG Clearance |
|
Re-inspection required |
2/17/26: gas piping is currently running through notched eave/ rafter tails (structural members may not be notched or bored to accommodate gas piping unless specifically engineered), engineer fix required for notches made at structural members, gas piping must be properly supported per IFGC 415.1 support of piping, gas piping must be grounded/bonded. |
| 02/24/2026 |
COT - BULD - SWG Clearance |
|
Passed |
Ok to set new meter and resume service: CODE: RECN |