Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/22/2026 | COT - RSEL - Electrical Final | Re-inspection required | Mini split has no tag/sticker showing specs and UL listing, please provide documentation Exposed electrical box under bathroom sink must be built up and finished. |
|
| 07/28/2026 | COT - RSEL - Electrical Final | Re-inspection required | 1. Bathroom receptacle needs to be GFCI if it's within 6 feet of a sink.. 2. Kitchen receptacle needs to be GFCI if it's within 6 feet of a sink. 3. Did not have access to subpanel provide access to subpanel to verify proper breaker sizes. 4. Missing dataplate information for mini splits. 5. Condenser needs to be a minimum of 6 inches from the wall and also needs to drop so that air doesn't get trapped under the Eave. 6. Disconnect for condenser is also sitting too high,please drop to about 6'5". |
|
| 08/14/2026 | COT - RSEL - Electrical Final | Passed |