Inspection Status: Re-inspection required

Inspection History: RSBU - Building Final 

Date Description Inspector Results Comments
07/22/2026 RSBU - Building Final  Re-inspection required Mini split has no tag/sticker showing specs and UL listing, please provide documentation
Exposed electrical box under bathroom sink must be built up and finished.
07/28/2026 RSBU - Building Final  Re-inspection required 1. Bathroom receptacle needs to be GFCI if it's within 6 feet of a sink..
2. Kitchen receptacle needs to be GFCI if it's within 6 feet of a sink.
3. Did not have access to subpanel provide access to subpanel to verify proper breaker sizes.
4. Missing dataplate information for mini splits.
5. Condenser needs to be a minimum of 6 inches from the wall and also needs to drop so that air doesn't get trapped under the Eave.
6. Disconnect for condenser is also sitting too high,please drop to about 6'5".
08/14/2026 RSBU - Building Final  Passed