Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSEL - Electrical Final
Permit Number - TC-RES-0224-01071
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2024 | COT - RSEL - Electrical Final | Not Ready | 6/28/24: not ready | |
07/11/2024 | COT - RSEL - Electrical Final | Not Ready | 6/28/24: not ready 7/11/24: not ready |
|
07/15/2024 | COT - RSEL - Electrical Final | Re-inspection required | 6/7/24: not ready 6/26/24: water hammer arrestor must be accessible, missing water hammer at hot water at laundry box, sediment trap missing at water heater, T&P must terminate to exterior of building, receptacles missing at laundry room, rain cap and storm collar missing at water heater vent, seal all penetrations through top plate, seal all penetrations through vapor barrier, properly secure wiring in wall. 7/15/24: panel schedule not complete, ARC-FAULT breakers required throughout, no power at laundry room (receptacle or light fixture), dryer vent shall not have screen, sediment trap is required downstream of appliance shutoff valve, anti-tip required at range, 2 circuits required at kitchen, multiple circuits tied in together (kitchen,outdoor light,laundry room). High loop at dishwasher not properly installed, secure T&P. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
|
07/18/2024 | COT - RSEL - Electrical Final | Passed |