Parcel: 140170260


Addresses:

1304 E IRVINGTON RD


Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Permit Number - TC-RES-0224-01071

Inspection Description - COT - RSME - Mechanical Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/26/2024 COT - RSME - Mechanical Final  Re-inspection required 6/7/24: not ready
6/26/24: water hammer arrestor must be accessible, missing water hammer at hot water at laundry box, sediment trap missing at water heater, T&P must terminate to exterior of building, receptacles missing at laundry room, rain cap and storm collar missing at water heater vent, seal all penetrations through top plate, seal all penetrations through vapor barrier, properly secure wiring in wall. Gas piping must be grounded
07/01/2024 COT - RSME - Mechanical Final  Re-inspection required 6/7/24: not ready
6/26/24: water hammer arrestor must be accessible, missing water hammer at hot water at laundry box, sediment trap missing at water heater, T&P must terminate to exterior of building, receptacles missing at laundry room, rain cap and storm collar missing at water heater vent, seal all penetrations through top plate, seal all penetrations through vapor barrier, properly secure wiring in wall. Gas piping must be grounded
7/1/24: dishwasher drain must be properly supported, T&P Drain must terminate 6" above grade and be UV coated, sediment trap at water heater not properly installed, secure electrical cables 12" from main panel, seal penetrations through top plate, seal penetration through vapor barrier, use proper adhesive at CPVC, combustion air required at laundry room,
07/18/2024 COT - RSME - Mechanical Final  Passed