Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 126162840


Addresses:

4021 E CALLE CHICA


Inspection Status: Re-inspection required

Inspection History: COT - RSPL - Rough Soil 

Permit Number - TC-RES-0223-03154

Inspection Description - COT - RSPL - Rough Soil 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/08/2023 COT - RSPL - Rough Soil  Re-inspection required 6/8/23: install min 5foot water column, some pipes are air vapor locked.
06/09/2023 COT - RSPL - Rough Soil  Passed 6-9-23: Plumbers have installed water column at 5', all underground plumbing is under water test. Okay to backfill trenches and prepare for subsoil compaction.