Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-RES-0223-03069

Parcel: 107030190


Addresses:

2042 W SILVER PL

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
02/07/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Not ready. Missing anchor bolts at exterior wall. 32" o.c per plan. Missing king studs at openings along with straps per plan. Hold downs are not in place and secured. Shear wall screw pattern is off and missing screws. Stopped inspection. 2/7/2024
03/05/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready Not ready per previous notes. 3/5/2024
03/20/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Not ready. Missing anchor bolts at exterior wall. 32" o.c per plan. Missing king studs at openings along with straps per plan. Hold downs are not in place and secured. Shear wall screw pattern is off and missing screws. Stopped inspection. 2/7/2024

Not ready per previous notes. 3/5/2024

3/20/24: per previous notes on 2/7/2024
03/27/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed