Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
| Date |
Description |
Inspector |
Results |
Comments |
| 05/23/2025 |
RSBU - Building Final |
|
Re-inspection required |
5-24-25, per homeowner, there are two separate permits and he had called a building final for the bathroom under permit# 0223-03014. I wasn't able to retrieve this permit to verify required inspections. I explained to customer that I would get back to him in the upcoming week and reschedule any outstanding inspections if needed. |
| 05/30/2025 |
RSBU - Building Final |
|
Re-inspection required |
5-30-25: missing "knockout"at subpanel, label breakers at panel, exterior receptacles must be weather resistant, paint/seal all exterior wood together with condensation line at rooftop, firefoam all penetrations at top plates inside storage structure, install light fixture at storage or cap where no exposed wires are visible, insulate hose bib and wrap with 10 mil tape, install vacuum breaker at hose bib, cut cleanout to grade, seal bathroom water closet, missing receptacle covers on back bedroom together with a smoke detector.Stopped inspection-a reinspection is required and additional items may be added. |
| 07/02/2025 |
RSBU - Building Final |
|
Passed |
7/2/2025 approved. |