Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 09/29/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
9/29/23 missing shot nails interior walls, anchor bolts outer perimeter and shear walls baring truss front room needs engineering letter of correction |
|
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
10/4/23: missing anchor bolts at shear walls need to be inside of shear walls within 12 inches of end of wall |
| 10/06/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
Corrections incomplete. |
| 10/10/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
10/10/23 South wall is 3' from property line, and does not meet the requirements of R302.1 as amended. Builder can continue at own risk. |
| 12/05/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
Duplicate inspection. 12/5/2024 |