Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Date Description Inspector Results Comments
02/04/2025 COT - RSME - Mechanical Final  Re-inspection required 2/4/25: Sediment trap required at furnace in attic, furnace B-vent requires 6" clearance from combustibles for single wall pipe and 1" clearance for double wall pipe, refrigeration lines on exterior of home must be fully wrapped or coated for UV protection, disconnect box attachment to house must be sealed.
02/11/2025 COT - RSME - Mechanical Final  Passed 2/11/25 corrections made
02/11/2025 COT - RSME - Mechanical Final  Re-inspection required 2/11/25 no answer at door, external pvc still not painted or uv protected