Permit: TC-RES-0125-00527

Parcel: 123023230


Addresses:

2710 E SENECA ST

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
05/27/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Tighten loose anchor bolts throughout. Add anchor bolt at marked area. Add anchor bolts that are out of the center third of bottom plate. Provide proper washers at ledger per detail. Rafters cannot sit on top of window header. Unless approved per engineer. Provide a continuous top plate and have a minimum of 24" overlap between the two plates on each end. Provide correct number of jacks studs per the plan. 5/27/2025
05/28/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Per previous notes. 5/28/2025
07/23/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 7/23/2025 corrections were made.