Permit: TC-RES-0125-00414

Parcel: 133412170


Addresses:

609 N LOQUAT AV

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical FinalĀ 

Date Description Inspector Results Comments
10/06/2026 COT - RSEL - Electrical FinalĀ  Re-inspection required 1. Improper counter receptacle spacing ;Missing receptacle on kitchen counter at 48 inches from the last receptacle from the right.
2. Per 2017 NEC section 210.52; Kitchen island receptacles cannot be installed below countertop that extends more than 6 inches; the current condition has the receptacles mounted under a 16 inch overhang.
3. Missing water-hammer arrestors at washing machine, dishwasher and ice maker.
4. Garage entry door needs to be 20 minute fire rated and solid core.
5. Install combination carbon monoxide/smoke detector in hallway.
6. Romex for waste disposal needs to be protected with conduit.