Permit: TC-RES-0125-00259

Parcel: 121012510


Addresses:

5913 E LESTER DR

Inspection Status: Not Ready

Inspection History: COT - RSEL - Electrical Final 

Date Description Inspector Results Comments
08/14/2025 COT - RSEL - Electrical Final  Not Ready All work complete; no record of other instructions being performed.
08/18/2025 COT - RSEL - Electrical Final  Re-inspection required 8/18/25: Receptacle spacing not per plan throughout (at bedrooms, living rooms, hallways) (E3901.2.1)(E3901.10)(E3901.4), GFCI required at both small appliance receptacles at kitchen, GFCI required at garbage disposal/ dishwasher receptacle, open Ground at multiple receptacles, open neutral at south west bedroom, cover plates required at 90 degree EMT fittings, all metallic boxes must be grounded (please remove receptacle to verify grounding), smoke detector in south west bedroom not interconnected with all others, EMT supports required throughout at 3' from outlet box, NM cable shall be protected from physical damage at laundry room, electrical not per approved plans (receptacles missing, lighting missing), exhaust fan in bathrooms must terminate outside of the home, ladder required for roof access to verify A/C amp size, properly secure liquid tight at main panel to junction box, properly secure junction box on top of main panel, open light fixture at laundry room, exposed canceling at laundry room, GFCI required at laundry room receptacles. STOPPED INSPECTION MORE ITEMS MAY BE ADDED.
08/29/2025 COT - RSEL - Electrical Final  Not Ready customer did not understand that approved plans on site for inspection.
09/05/2025 COT - RSEL - Electrical Final  Re-inspection required 1-Smoke detector in SW bedroom is not working.
09/09/2025 COT - RSEL - Electrical Final  Passed