| 10/03/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | -Provide approved plans. 2-seal fire-blocking throughput. |
|
| 10/08/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | Called and received no answer, with no call back. Got to the site and received no answer. Need access to the site. 10/8/2025 | |
| 10/09/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | NM cable not rated to run in hollow cavity filled with grout. Both at south wall. Seal both exterior penetrations for lighting and receptacle. Provide 12/2 wire for exterior receptacle. 10/9/2025 | |
| 10/13/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Approved. 10/13/2025 |