Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 01/29/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Partial Pass |
Garage |
| 05/07/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
5-7-25, add nails to sheathing-nails shall not overpenetrate more than 1/16", add blocking over door & add nails along edges, add blocking to bathroom, sister 2x6 where over 16" o.c., missing A-34's where required per plan. |
| 05/08/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Partial Pass |
previous corrections completed. left open to use for brick ties. |
| 09/09/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
9/9/2025 brick ties are in place. |
| 12/09/2024 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Partial Pass |
porch |