Parcel: 10604041A


Addresses:

324 E PRINCE RD


Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Final 

Permit Number - TC-RES-0124-00336

Inspection Description - COT - RSEL - Electrical Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/13/2024 COT - RSEL - Electrical Final  Re-inspection required Provide two circuits at kitchen. Add receptacle near refrigerator. Provide gfci breaker for garbage disposal. Receptacle in bathroom not gfci. Receptacle on roof not working. Possible buried receptacle in hallway. Remove covers from smokies. Provide lock shackles at water heater breakers. Provid hammer arrestor on hot line for dishwasher. Give a high water loop for dishwasher. 11/13/2024