Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-RES-0124-00336
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/13/2024 | RSBU - Building Final | Re-inspection required | Provide two circuits at kitchen. Add receptacle near refrigerator. Provide gfci breaker for garbage disposal. Receptacle in bathroom not gfci. Receptacle on roof not working. Possible buried receptacle in hallway. Remove covers from smokies. Provide lock shackles at water heater breakers. Provid hammer arrestor on hot line for dishwasher. Give a high water loop for dishwasher. 11/13/2024 |