Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSME - Mechanical Final
Permit Number - TC-RES-0124-00336
Inspection Description - COT - RSME - Mechanical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/13/2024 | COT - RSME - Mechanical Final | Re-inspection required | Provide two circuits at kitchen. Add receptacle near refrigerator. Provide gfci breaker for garbage disposal. Receptacle in bathroom not gfci. Receptacle on roof not working. Possible buried receptacle in hallway. Remove covers from smokies. Provide lock shackles at water heater breakers. Provid hammer arrestor on hot line for dishwasher. Give a high water loop for dishwasher. 11/13/2024 |