| 07/31/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Not Ready | Not ready hold down is not in place stopped inspection | |
| 08/16/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Not ready hold down is not in place stopped inspection 8/16/24: Hold downs missing throughout and not placed in correct location, Anchor bolt spacing at exterior wall and interior bearing walls not per plan, hangers missing throughout, (3) 2X12 header missing at bathroom per plan, properly fasten all hangers and clips throughout, provide truss clacs. |
|
| 08/30/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | Ok to,cover exterior walls |