Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/06/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | partial pass for exterior sheathing | |
| 08/28/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 8/28/24: anchor bolts spacing not per plans, anchor bolts shall be placed no more than 12" from edge of sill plate, sheathing must be properly fastened at south west corner of garage, beam to post connection at garage calls for Simpson ACE6 clip, shot pins at non bearing wall not per schedule (spacing is greater than 48" o.c and greater then 6" from edge of bottom plate, framing not per plans (door opening for storage room covered and storage room not framed, shearing on exterior not completed on west side of garage, ensure vents are installed. | |
| 09/04/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 8/28/24: anchor bolts spacing not per plans, anchor bolts shall be placed no more than 12" from edge of sill plate, sheathing must be properly fastened at south west corner of garage, beam to post connection at garage calls for Simpson ACE6 clip, shot pins at non bearing wall not per schedule (spacing is greater than 48" o.c and greater then 6" from edge of bottom plate, framing not per plans (door opening for storage room covered and storage room not framed, shearing on exterior not completed on west side of garage, ensure vents are installed. 9/4/24: partial pass at garage for framing and roof nailing |
|
| 10/30/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10/30/25 passed |