Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
| Date |
Description |
Inspector |
Results |
Comments |
| 04/05/2024 |
COT - RSEL - Electrical Final |
|
Re-inspection required |
Subpanel must be labeled area specific for each breaker, faceplate needed for receptacle left side of front door, kitchen sink missing hammer arrestor for dishwasher, dishwasher discharge pipe/tubing must rise to underside of counter and be fastened, outlet receptacle not complete between kitchen countertop gap, kitchen receptacles must be gfci protected. |
| 04/08/2024 |
COT - RSEL - Electrical Final |
|
Passed |
|