Permit: TC-RES-0123-02113

Parcel: 131081400


Addresses:

5911 E 27TH ST

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Romex wire appears to be unattached to the framing within 12" of the electric boxes. Open all walls 18" above all wall outlets and switches for field inspection. They new PEX and ABS appear to be compliant, however it also was installed without permit and inspection. The new roof package unit and interior air handler appear compliant and fused per manufacture's specs.
04/26/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed