Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 08/13/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Not Ready |
Not ready, currently at Pre slab. Added all the other missing inspections only building final was on this permit. |
| 09/18/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
9-18-25: add nails to roof sheathing on 2 panels located southwest area of roof, install Simpson BC6 clips at beam to posts connections-see plans for details, missing 2x6 ledger, posts to beams were not built per plans-The plans show the beams to lying directly on the posts and without any notching of the posts. |
| 10/01/2025 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
10/1/25 corrections made |