Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
03/10/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 3-10-26: missing blocking at registers, 12" clearance between pen lines and can lights is required-either relocated allowing for clearance or block using drywall, osb, plywood or 2x4. Add strap to laundry vents. Add bank plate at marked locations, Strap condensation line at kitchen, seal penetration at copper line in kitchen.
03/11/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 3-11-26: intermediates approved.